149
Nynja Build Manual 1.4d
Fig 185 mark cut line
i) When happy with fit drill and fix in place with white aluminium 4mm rivets.
Evenly spaced at 65mm or so.
Fix initially with clecos then ensure all swarf is removed before final riveting.
Fig 186 final fixing
j) Fix the front to the door pillar tubes (SKR34) using three 4mm aluminium
rivets each side.
Countersink the rivets using a 10mm drill bit to countersink the
glassfibre so the rivets sit flush.
k) Fix the rear edge with 4x10 white plastic screws and self locking plastic nuts.
l) Cut slot in floor to allow flap detent lever to pass through
– see Figure 181