Expanding and Upgrading HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
9-2
HiPath 3000/5000 V9, Service documentation
exup.fm
HiPath 3000Expanding
9.1
HiPath 3000Expanding
The following section provides information on supplementary equipment or extensions that are
not described in Chapter 4, “Installing HiPath 3000”.
9.1.1
Replacing Peripheral Boards for HiPath 3800
HiPath 3800 lets you remove and insert peripheral boards during operation (hot plugging). The
following startup rules apply.
Rules for removing and inserting boards
7
Caution
Always wear an antistatic wristband when working on the system (especially when
handling boards).
7
Caution
To ensure that the system operates without blocking, you must follow the rules in
Section 4.1.5 concerning board configuration.
Table 9-1
Startup Rules for Inserting and Removing Boards
If
Then
Inserting new board
in free slot
Board is integrated into the system according to the rules for initial
startup (Section 4.1.5.6).
●
System with default numbering plan
The station numbers from the new board are appended (consec-
utively and in ascending order) to the numbers already assigned.
●
System with modified numbering plan
The station numbers on the new board can be in any order.
Using HiPath 3000/5000 Manager E or Assistant T, you can assign a
specific station to a port. If the number is already assigned to a differ-
ent object, you can switch both numbers.
Replacing board with
same or un-
derequipped board
type
Board is activated. The same station range is used.
Summary of Contents for HiPath 3000 Series