boards.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
3-159
Nur für den internen Gebrauch
Boards for HiPath 3000
Peripheral boards
Cover
To ensure sufficient shielding, provide the board with a shielding panel. For information on
mounting the shielding panel, see Section 4.1.5.3.
LED statuses and their meanings
Cable and connector assignment
●
For connecting to the SIVAPAC connector on the backplane: Table 3-75
●
For connecting to the connector panels using RJ45 jacks: Table 3-76
●
For U.S. only: For connecting to the connector panels with CHAMP jack: Table 3-77
●
For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-78 and
Table 3-79
Table 3-68
SLMAE8, SLMAE - LED Statuses
Red LED
Green
LED
Status
Action
Off
Off
Board not receiving power or not plugged in
correctly.
Board is out of order.
Check plug contact on
board.
On
Off
Board is receiving power and board test is
in progress.
Board is defective if status remains un-
changed (board test unsuccessful).
Replace board.
Loadware loading not successfully com-
pleted. Board is faulty.
Replace board.
Error detected on board.
Board is deactivated (not applicable to er-
rors detected by test loops) or board was
deactivated using HiPath 3000/5000 Man-
ager E.
Check whether the board
was deactivated using Hi-
Path 3000/5000 Manager
E. If not, replace board.
Flashing
Off
Loadware is being loaded.
Off
On
Board test completed successfully. Board is
OK (idle state).
Off
Flashing At least one subscriber line circuit is activat-
ed.
Summary of Contents for HiPath 3000 Series