boards.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
3-81
Nur für den internen Gebrauch
Boards for HiPath 3000
Peripheral boards
3.3.1
DIU2U (for U.S. only)
Introduction
The DIU2U (Digital Interface Unit 2 Universal) trunk module connects two digital trunks to Hi-
Path 3800 and in this way provides two primary rate interfaces (PRI) ISDN via T1 interfaces.
Connection types
●
Fiber optic cable
The fiber optic cable is only connected via the front panel. The opto-electronic converter
must be used to connect a fiber optic cable to the 15-pin Sub-D jacks on the front
panel.
●
Copper cable
The copper cable is connected to T1-CSU (Customer Service Unit) or DSU (Data Service
Unit) via the adapter cable (C39195-A7269-B625) shown in Figure 3-30.
Adapter cable C39195-A7269-B625
Figure 3-30
DIU2U (for U.S. only) Adapter Cable C39195-A7269-B625
Table 3-29
DIU2U (for U.S. only) - adapter cable assignment (C39195-A7269-B625)
15-pin Sub-D
connector
Pin
50-pin Amphenol con-
nector
Pin
Function
Color code
9
38
a-wire (T), transmit
wht/blu
1
13
b-wire (R), transmit
blu/wht
Summary of Contents for HiPath 3000 Series
Page 1252: ......