Boards for HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
3-334
HiPath 3000/5000 V9, Service documentation
boards.fm
Peripheral boards
3.3.42
TMGL4 (for U.S. only)
Introduction
A TMGL4 trunk module connects up to four analog ground-start or loop-start trunks to HiPath
3550 and HiPath 3350.
Ground start is the default.
Interfaces
>
NOTE
Danger of damage to property due to surge voltage. The required lightning protec-
tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec-
tion”.
7
Warning
You must disconnect the power and remove the slip-on connectors from the TMGL4
board before removing it from the system.
Do not connect the slip-on connectors to the TMGL4 board until the board is seated
in its slot and the system power is on.
Failure to follow these instructions may severely damage the system.
Figure 3-114
TMGL4 (for U.S. only) - Interfaces (S30810-Q2918-X)
X1
50
2
TMGL4 board
1
8
To CUP/
CUC
X2
To trunks
X3
To ANI4