Boards for HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
3-254
HiPath 3000/5000 V9, Service documentation
boards.fm
Peripheral boards
Assigning the CAS cable
The following options are available for connecting network terminators (NT), multiplexers
(MUX) or modems to the TCAS-2 and TCASR-2 cards (MINI BNC connections):
●
Coaxial trunk (75 ohms), length = 10 m
●
symmetrical line (120 ohms)
The impedance converter F31505-E1-A146 must be used for connecting to a symmetrical
trunk.
Table 3-119
TCAS-2, TCASR-2 (for selected countries only) – Assignment of the CAS
Cable C39195-A7700-B13
Wire
Function
MINI BNC connec-
tor
BNC connector
1
Receive, Tip
Conductor
Conductor
Receive, Ring
Shield
Shield
2
Transmit, Tip
Conductor
Conductor
Transmit, Ring
Shield
Shield
Figure 3-86
TCAS-2, TCASR-2 (for selected countries only) – CAS Cable C39195-
A7700-B13
MINI BNC connector
Ferrite core
BNC connector