Boards for HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
3-350
HiPath 3000/5000 V9, Service documentation
boards.fm
Peripheral boards
The operating mode (short or long line with the appropriate flash times) can be set up for each
subscriber line interface with HiPath 3000/5000 Manager E (the menu settings: Set up station
–> Station –> Param –> Flags).
Technical connection conditions
●
Maximum supply current: approximately 34 mA; maximum supply voltage: approximately
40 V DC
●
Ring voltage against negative supply voltage (a-wire (tip)/RING): two telephones maxi-
mum
●
Range, see Section 2.7
●
Loop current detection > 10 mA
●
Ground button detection > 20 mA
●
The transmission technology is set according to the specific country through the respec-
tively entered country code (for country initialization, see Chapter 5, “Starting Up HiPath
3000”).