Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
4.2.4.2
Selecting the Installation Site
Selecting a site
The customer usually has a preferred installation site in mind, for example an existing 19-inch
cabinet.
Make sure that the customer’s site meets the following guidelines:
●
To guarantee sufficient system ventilation, allow a minimum of 10 cm clearance around the
housing.
●
Do not expose the systems to direct sources of heat (for example sunlight and heaters).
●
Do not expose the systems to extremely dusty environments.
●
Avoid contact with chemicals.
●
Take every precaution to prevent the formation of condensation on the system during op-
eration. Systems covered with condensation must be dried before being used.
●
Observe the environmental conditions specified in Section 2.11.
Information on the design can be found in the following sections:
●
●
4.2.4.2.1
For U.S. only: Power plug
The AC connection must fulfill the requirements specified in Table 4-13.
Table 4-13
Electrical Connection Values (for U.S. only)
Nominal
voltage
Nominal voltage range
Nominal Frequency
Range
Wall Outlet Configura-
tions
from
to
from to
120 V AC/
60 Hz
110 V AC
130 V AC
47 Hz
63 Hz
NEMA 5-15, 2-pin, 3-
wire, earth