Trunk Boards
Table 2-11
Trunk Boards for HiPath 3550
Board
Name
Capacity
Coun-
try
Type/Description
P
o
rt
s per board
B channels per board
Max. n
u
mber of
boards per system
RO
W
USA
TCAS-2
2
60
1
1
TCAS-2 provides two E1 CAS interfaces which, combined, can support up to 60 B channels. As HiPath 3550 supports a
maximum of 30 B channels, a total of up to 30 B channels may be used.
1
x
2
2
For selected countries only
-
Board for supporting country-specific
CAS (Channel Associated Signaling) protocols
TLA
2
#
3
x
-
Trunk board for analog lines
TLA4
4
x
-
Trunk board for analog lines
TLANI2
2
x
x Trunk board for analog lines including ALUM
TLANI4
4
x
x Trunk board for analog lines including ALUM
TLANI8
8
x
x Trunk board for analog lines including ALUM
TLA8
8
x
-
Trunk board for analog lines
TS2N
30
30
1
x
-
Board for primary rate access; can be used for tie trunk traf-
fic.
In HiPath 3000/5000 V5.0 and later, the B channels in the
TS2N board are subject to license. Consequently, the
TS2N boards (S30810-Q2913-X300) have been assigned
a new hardware identification code. The new code prevents
the board from being used in earlier versions. Functionality
and layout of the board have not been changed.
STLS2
2
4
x
-
Board for ISDN basic rate access.
Configuration of ISDN trunks, tie trunks, and stations (no
feeding) on the same board is possible.
STLS4
4
8
x
x
TST1
1
24
1
-
x PRI board
TMGL4
4
-
x Trunk board for analog lines
TMQ4
4
8
-
x BRI board
Summary of Contents for HiPath 3000 Series