Boards for HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
3-302
HiPath 3000/5000 V9, Service documentation
boards.fm
Peripheral boards
7.
Make the following settings in the ECGM tool:
●
File/Options
menu: Select the service PC’s COM interface (for example:
COM1)
●
File/Install Software
menu: Select the file
E1v0xx.pnm
(for exam-
ple,
E140ah.pnm
from the directory
ecginst
.
●
File/Install Edb
menu: Select the file
Ecg_edbv.ein
(for example
Ecg_edb4.ein
) from the directory
ecginst
.
●
File/Update Site
menu:
–
Under ECG SOFTWARE, select loadware file
E1v0xx.pnm
.
–
Under “ECG EDB”, select file
vbrazil.iyy
.
–
Under “FILE NAME”, select file extension
.db
for logging TMCAS
events.
–
Enter the customer name under “ECG NAME”.
8.
Close the ECGM tool and then restart (
ecgm.exe
).
9.
Enter the COM interface under “COMM” and the customer name in the
Set-
tings/ECG Name
menu. All other windows are updated automatically.
10.
Channel configuration
Define the channel parameters in the
View/Database
menu (reserve unused
channels with “Out of Service”.):
●
Protocol
●
Signaling method (incoming and outgoing)
●
Clock master (always central office)
●
Operator number (corresponds to the number of the attendant console of the
HiPath 3000)
11.
Software download
If the seven-segment display H1 on the TMCAS displays “H”, it is necessary to
download the extender software (
Download/Extender
menu). Otherwise, con-
tinue with the next step.
12.
Start the software/database download using the
Download/Software and
Database
menu. This procedure takes approximately 8 minutes.
The download is complete when the configured channels display the “Idle” status.
The seven-segment display H1 on the TMCAS shows “A” (= active).
Step
Activity