Installing HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
4-102
HiPath 3000/5000 V9, Service documentation
inst_h3.fm
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
●
Note: The MDF cable reverses the signals coming from the board. This means that R/T on
the board interface becomes T/R on the Amphenol connector.
HiPath 3550 and HiPath 3350: connecting the LAN cable for HXGS3
LAN cables are connected to HXGS3boards in a HiPath 3550 or HiPath 3350 according to the
description in Section 3.3.4.
●
Electromagnetic shielding
To ensure sufficient electromagnetic shielding (according to EN 55022), a shielded LAN
cable must be used, or the LAN cable being used must already be shielded.
●
Procedure: LAN cable shield contacts
4.2.3.9
Attaching Ferrite
To keep within the interference limit required by EMC Class B, you must attach ferrite to the
following lines.
HiPath 3550 and HiPath 3350 power cables (wall housing)
The wall housing’s power cable must be guided through the C39022-Z7000-C7 ferrite sleeve
that is included in the accessory pack. Position the ferrite sleeve as shown in Figure 4-56 so
that you will be able to close the housing cover.
Step
Activity
1.
Expose the external shield (D) by stripping the LAN cable sheath (A).
Stripped length = approx. 30 mm.
2.
Wrap conductive tape (C) around the exposed external shielding at least
1.5 times and use a cable binder (B) to attach it to the housing, maintaining
a continuous conducting contact between the tape and the housing (see
figure).
A
Stripped length
B
C
D