Starting HiPath 3000 as a Gateway
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
7-8
HiPath 3000/5000 V9, Service documentation
start_3g.fm
Starting HiPath 3300 as a Gateway
7.3
Starting HiPath 3300 as a Gateway
7.3.1
Prerequisites
Refer to Section 4.2.1 for information on the tools and resources needed to install the HiPath
3300 system.
7.3.2
Procedure for Installation and Startup
7
Warning
Only authorized service personnel should install and start up the system.
>
To ensure that IP addresses are not assigned more than once in the customer net-
work, you must ping each new IP address to be configured before each IP address
is assigned. If an IP address responds, then this address cannot be used again.
7
Caution (for Brazil only)
The use of the outlet strip with overvoltage protection with part number C39334-
Z7052-C33 is absolutely mandatory. The AC power of the system must be conduct-
ed through the outlet strip with overvoltage protection.
Table 7-3
HiPath 3300 as a GW, Procedure for System Installation and Startup
Step
Activity (Remarks)
HiPath 3300 Installation (19-Inch Cabinet) (Section 4.2)
1.
Selecting the Installation Site, page 4-111 (usually predetermined)
2.
Unpacking the Components, page 4-112
3.
Not for U.S.: Attaching a HiPath 3500 and HiPath 3300 to the Wall, page 4-113
4.
Installing a HiPath 3500 or HiPath 3300 in a Cabinet, page 4-114
5.
Grounding the System, page 4-116
6.
Connecting Cables and the Line Network, page 4-118
7.
Summary of Contents for HiPath 3000 Series
Page 1252: ......