boards.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
3-125
Nur für den internen Gebrauch
Boards for HiPath 3000
Peripheral boards
LED statuses and their meanings
Table 3-52
SLA8N (not for U.S.), SLA16N, SLA24N - LED Statuses
Red LED
Green
LED
Status
Action
Off
Off
Board not receiving power or not plugged in
correctly.
Board is out of order.
Check plug contact on
board.
On
Off
Board is receiving power and board test is
in progress.
Board is defective if status remains un-
changed (board test unsuccessful).
Replace board.
Loadware loading not successfully com-
pleted. Board is faulty.
Replace board.
Error detected on board.
Board is deactivated (not applicable to er-
rors detected by test loops) or board was
deactivated using HiPath 3000/5000 Man-
ager E.
Check whether the board
was deactivated using Hi-
Path 3000/5000 Manager
E. If not, replace board.
Flashing
Off
Loadware is being loaded.
Off
On
Board test completed successfully. Board is
OK (idle state).
Off
Flashing At least one station is activated.