Service and Maintenance Tasks
●
Procedure: After replacing the board, load the “old” CDB from the customer disk to
the system
Step
Activity
1.
Back up current CDB with HiPath 3000/5000 Manager E.
2.
Disconnect the system from the power supply.
3.
Remove the MMC.
4.
Replace the central control board.
5.
Insert the MMC.
6.
Restart the system by plugging in the power plug.
7.
Reload.
8.
If an “older” CDB update is imported, reload the CDB into the system with-
out the Delta mode. The “hardware and CDR switch” remain inactive.
9.
Reset. The customer system is now configured. All you have to do now is
●
log on the CMI mobile telephones again,
●
reset the V.24 baud rate,
●
re-configure the ACD login port,
●
redefine all telephone configurations, such as volume and display, per
station.