Boards for HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
3-224
HiPath 3000/5000 V9, Service documentation
boards.fm
Peripheral boards
Figure 3-69
Wiring and Ranges for S
0
Bus Jacks (not for U.S.)
The connecting cord of the
ISDN telephone must not be
longer than 10 m.
To switch from external to inter-
nal S
0
operation, you must first
cross the SR and SX wires be-
fore the first jack.
UAE
Connec-
Additional
power sup-
ply
230 V~
Mini-Western
through-jack
(MW8 = 8-pin)
SR.1 Receive 5
SX.1 Transmit 3
SX.2 Transmit 6
SR.2 Receive 4
1st Mini-Western jack
(MW8 = 8-pin)
2nd to 8th Mini-Western jack
(MW8 = 8-pin)
100
Ω
/0.25 W
Terminating resistor in last jack
System
S
0
1 to S
0
4
*
Twisted
pair
8
1
7 6 5 4 3 2
SX
SX
SR
SR
* = Not crossed in TA-S
0
8
1
7 6 5 4 3 2
8
1
7 6 5 4 3 2
6
4
5
3
Maximum ranges:
System
3
1
2
8
Short bus: 150 m (492 ft.)
Long bus: 150 m (492 ft.)
20m
Summary of Contents for HiPath 3000 Series
Page 1252: ......