start_h3.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
5-15
Nur für den internen Gebrauch
Starting Up HiPath 3000
Starting Up HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300
5.2.3
Carrying Out a System Reload
After supplying the system with power, you must carry out a system reload. This can be per-
formed during the initial system boot.
Procedure
Press and hold down the reset switch for at least 5 seconds (RUN LED goes out). If you do not
hold down the reset switch for a full 5 seconds, the system may perform a reset rather than a
reload or may not reload properly.
5.2.4
Carrying Out the Country Initialization and Selecting the
Password Type
Carry out the country initialization on the system telephone with the internal station number 100
(HiPath 3550 and HiPath 3500) or 11 for (HiPath 3350 and HiPath 3300) (port 01). This process
loads the country-specific language and features and ensures that the system meets the coun-
try’s conditions for approval.
In Germany, no country adaptation is required after a reload because the system boots with
the German country code by default.
The next step involves selecting the password type.
Input procedure
>
Since the system software no longer provides all languages, some systems no long-
er start up in the customary local language after the country code is entered. You
must now load the local language prior to country initialization, using HiPath
3000/5000 Manager E (see information on multilingual text output in the Feature De-
scription HiPath 3000/5000).
After carrying out the country initialization, but before loading the required local lan-
guage, the displays come up in German.
Table 5-7
Entering the Country Code and Selecting the Password Type
Step
Input
Description
1.
*95
Start system administration
2.
31994
Default user name
3.
31994
Default password
4.
XXXXX
You are prompted to enter a new password (max. 15 digits).
5.
XXXXX
You are prompted to confirm the password entered in step 4.
6.
29-5
Country initialization
Summary of Contents for HiPath 3000 Series