Boards for HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
3-336
HiPath 3000/5000 V9, Service documentation
boards.fm
Peripheral boards
3.3.43
TMGL4R (for U.S. only)
Introduction
A TMGL4R trunk module connects up to four analog ground-start or loop-start trunks to HiPath
3500 and HiPath 3300.
Ground start is the default.
Interfaces
>
NOTE
Danger of damage to property due to surge voltage. The required lightning protec-
tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec-
tion”.
Figure 3-115
TMGL4R (for U.S. only) (S30810-K2918-Z)
>
If ANI4R is installed as option 1 or 2, TMGL4R board must be inserted in slot 4, 6 or
8 (slots 6 and 8 are not available with HiPath 3300).
X1
50
2
to CUPR/
CUCR
X4 (4 MW4 jacks)
11
To trunk 1
:
:
:
To trunk 4
To ANI4R
1
X5 (MW10 jack)
To GEE
X3
44