Identifying System Power Requirements
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
D-6
HiPath 3000/5000 V9, Service documentation
power_calc.fm
HiPath 3350 Board Power Requirement
D.3
HiPath 3350 Board Power Requirement
Table D-5
Nominal Output of the HiPath 3350 Power Supply Units
Power Supply Unit
Part Number
Max. Nominal Output in W
5 V
–48 V
S30122-K5658-M
15.0
19.2
S30122-K5660-A300
S30122-K5660-M300
20.0
1
1
Nominal output = 40 W. Due to build-up of heat, not more than 20 W may be withdrawn.
53.0
S30177-U773-X with
S30122-K7686-M1
–
110
>
You must check whether the total power requirement of the boards used and the
workpoint clients connected exceeds the maximum possible output of the PSUP or
the UPSC-D with or without Powerbox PB3000. Section D.7 contains a sample cal-
culation.
Table D-6
HiPath 3350 Board Power Requirement
Board or Component
Part Number
Net Power Requirement in
W
5 V
–48 V
S30807-H5482-X
–
2.0
S30807-H5485-X
–
3.0
(including sub-
boards)
S30810-Q2935-A301
7.0
0.5
S30817-Q951-Axxx
0.5
–
S30817-Q951-Axxx
0.5
–
S30817-Q951-Axxx
0.5
–
(in old systems
incl. fan kit)
S30810-Q2943-X, S30810-Q2943-X1
10.0
2.8
S30122-Q7379-X100
2.6
0.3
DM1
S30807-Q5692-X100
–
5.0
S30810-H2956-X100
2.0
1.0
S30810-H2956-X200
2.0
1.0
S30810-Q2957-X
2.5
1.5
1