Starting Up HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
5-4
HiPath 3000/5000 V9, Service documentation
start_h3.fm
Starting Up HiPath 3800
5.1.2.1
Assigning Station Numbers
The first time the system is initialized, the system determines its capacity and stores the result
in the CDB (customer database). After each system reset, the system accesses this data and
generates a continuous numbering plan.
If the system detects changes to the board configuration during startup, the following action is
taken:
If
Then
Missing or defective board
No action.
Different board type
The system does not automatically activate the board.
Underequipped or same
board variant
Board is activated. The same station range is used.
Over-equipped board vari-
ant
Board is activated. The old station range is activated and the
ports associated with the new board are inserted at the end.
The ports are split if there is no contiguous station range avail-
able.
New board in empty slot
●
Board was the last one installed in accordance with the
placement sequence:
All boards are activated and the numbering plan continues
without a gap.
●
Board was inserted ahead of another board in the place-
ment sequence:
Board is activated and appended to the last board in the
numbering plan.
Summary of Contents for HiPath 3000 Series
Page 1252: ......