Starting Up HiPath 3000
Starting Up HiPath 3800
Procedure: Reinitialization
Proceed as follows if measures to expand the system configuration require reinitialization of
the numbering plan:
Step
Activity
Description
1.
Disconnect the system from
the power supply. Check that
the system is de-energized.
Expand as required.
2.
Connect system to power sup-
ply
A continuous numbering plan is generated (as was
the case when the system was first initialized).
Notes:
●
Changes to the extension numbers result in
changes to the individual, extension-specific
data.
●
Only those ports provided for in accordance
with the maximum configuration are activated if
the maximum line configuration is exceeded
(too many trunk boards).
●
A mixture of subscriber line circuits and trunk
lines on one S
0
board can result in gaps in line
numbering. This is because all S
0
ports are ini-
tially activated as trunks and are only subse-
quently reconfigured.