boards.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
3-27
Nur für den internen Gebrauch
Boards for HiPath 3000
Central Board
Outputs, interfaces
●
Ethernet (10 BaseT)/10 MBit) LAN interface, only in CBRC S30810-Q2935-Z40
The interface can, for example, be used for the following applications:
–
For administration using HiPath 3000 Manager E
–
For the TAPI 120/170 connection via the CSTA interface. Bear in mind, however, that
the number of BHCAs (Busy Hour Call Attempts = number of connection attempts dur-
ing busy traffic hours) is restricted to 400 at a maximum of six CSTA links for the TAPI
120/170 connection. The use of “power dialers” is not approved.
–
For the output of call data
The ETHERNET-LAN interface is deactivated by the system software deactivated as soon
as an HG 1500 board is inserted.
●
Eight digital U
P0/E
subscriber lines
For example, U
P0/E
workpoint clients or BS3/1 base stations for HiPath Cordless Office can
be connected here.
●
Four analog T/R subscriber lines
For U.S. only: These interfaces do not support the connection of external extensions via
OPS (Off-Premises Station) signaling.
CBRC S30810-Q2935-Z401: The interfaces supply a ring voltage of approx. 65 V
eff
.
CBRC S30810-Q2935-Z301: The T/R interfaces supply a ring voltage of approx. 35 V
eff
.
Depending on the terminals connected, we cannot exclude the possibility of errors occur-
ring during ringing state.
●
Two digital S
0
interfaces (CO (default) or station)
●
Backplane (CUCR or CUPR) connection via slots 1 (X11), 2 (X5) and 3 (X6)
●
Music on Hold: MPPI, MUSIC or EXMR
●
Options bus (O bus)
●
V.24 interface