Starting Up HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
5-2
HiPath 3000/5000 V9, Service documentation
start_h3.fm
Starting Up HiPath 3800
5.1
Starting Up HiPath 3800
This section contains information on how to start up the HiPath 3800 communication system.
5.1.1
Startup Procedure
5.1.2
Supplying the System with Power
7
Warning
Only authorized service personnel should start up the system.
7
Danger
The system may only be started (connected to the power supply) if all system cabi-
nets are sealed at the rear with the connection and filler panels provided.
Table 5-1
HiPath 3800 - Startup Procedure
Step
Startup Activity (Remarks)
1.
Supplying the System with Power, page 5-2
(Plugging in the power supply cable for the system cabinet(s) and positioning the
switches for all LUNA2 power supplies to “DC-ON” –> starting system boot)
2.
Carrying Out a System Reload, page 5-6
3.
Carrying Out the Country Initialization and Selecting the Password Type, page 5-7
4.
Not for U.S.: Entering the System Number, page 5-9
5.
Customer-Specific Programming, page 5-10
6.
Performing a System Check, page 5-10
7
Caution (for Brazil only)
The use of the outlet strip with overvoltage protection with part number C39334-
Z7052-C33 is absolutely mandatory. The AC power of the system cabinet(s) must
be conducted through the outlet strip with overvoltage protection.