boards.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
3-45
Nur für den internen Gebrauch
Boards for HiPath 3000
Central Board
Replacing the Backplane
Replacing the backplane may be necessary due to contact problems. These are evidenced by
the following symptoms:
●
Error messages about various peripheral modules occur.
●
Erratic error messages about the CBCC/CBRC and UPSCD modules occur.
●
The system zdisplays the error message
B16-12 RESTART: Power down
and performs
a restart.
Please note, however, that the backplane should only be replaced if the errors still occur even
after the following points have been checked and the mentioned problems eliminated:
●
Have the necessary grounding regulations been followed?
●
Do the cables have contact problems or visible damage?
●
Do the system components have any visible damage?
The following part numbers must be used to order the necessary replacement parts for HiPath
3500:
Replacing the backplane is described in Section 4.2.5, “Replacing the Backplane”.
L37911-A10-A18: HiPath
3500 Box, incl. UPSCDR
S30777-Q750-Z:
HiPath 3500 Backplane CUCR
Summary of Contents for HiPath 3000 Series