wclient.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
10-21
Nur für den internen Gebrauch
Workpoint Clients
OpenStage Product Family
Sorting the caller list
The display of the missed calls list is based on the local connection protocol interface of Open-
Stage 80. The call numbers on the missed calls tab are displayed in chronological order starting
with the latest call.
Key modules
2 “OpenStage Key Module 60/80” modules:
●
12 programmable keys
●
Each key can be programmed as a function, DSS or trunk key
●
Up to two “OpenStage Key Module 60/80” modules can be con-
nected to the telephone.
Connections
●
USB-A (master interface) for first-party CTI
●
121TR9-5* for headset, 8 pins
●
Bluetooth
●
Port for key module
●
For TDM only: USB-B (slave interface) for first-party CTI
●
For CorNet-IP (HFA) only: LAN port (10/100 Base-T)
●
For CorNet-IP (HFA) only: Integrated Ethernet switch for con-
necting to a PC
Additional features
●
Full-duplex speakerphone mode
●
Open listening
●
Voice dialing
●
Polyphonic and mp3 ring tones supported
●
No wall mounting
IP features [for Cor-
Net-IP (HFA) only]
●
CorNet-IP (HFA) based on H.323
●
Security and Encryption for H-Series Multimedia Terminals
H.235 Annex D
●
Voice codecs G.711, G.729, G.722
●
DHCP, FTP, HTTP, HTTPS, SNMP
●
Port-Based Network Access Control 802.1x
●
QoS based on DiffServ
●
VLAN
●
IEEE 802.3af Power over Ethernet (PoE)
Feature
Description