Service
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
12-54
HiPath 3000/5000 V9, Service documentation
service.fm
Guided Maintenance
12.4.10
Event log for HiPath 3000
HiPath 3000 features an event log where accrued errors are classified according to error class
and error number with the date/time of the original error. You can use HiPath 3000/5000 Man-
ager E to read out the event log.
Section 12.4.16 contains information on the possible entries.
12.4.11
Testing Telephones
After startup and country adaptation, you can activate the terminal test on any optiPoint 600
office (in U
P0/E
mode), OpenStage, optiPoint 410 and optiPoint 420 telephone using a code or
the service menu.
It is not possible to perform the terminal test on optiPoint 410 S and optiPoint 420 S telephones.
This test checks the display (your number is displayed), LEDs, and ring tones. The tests ends
automatically after a period of time. The test allows you to perform a visual and acoustic check
of the components to ensure that they are functioning properly.
Test procedure on the system telephone
The phone number, date and time are normally shown in the display. If a different text appears
(“Gateway not found”, for example), this means that there is an error.
Correct the error by following the administration instructions for the relevant telephone.
Table 12-6
Phone test
Step
Input
Description
1.
*940
Code for terminal test
2.
–
For approximately five seconds, all LEDs blink quickly (ex-
cept for the Service menu LED), all display pixels are acti-
vated, and you can hear a tone.
>
If the test does not react as described, an additional power supply (plug-in power
supply unit) for the relevant system telephone may be necessary.