service.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
12-85
Nur für den internen Gebrauch
Service
Guided Maintenance
30-017 !HEATER OFF -
HXG3
Temperature in Hi-
Path 3550/HiPath
3350 wall housing
is normal.
None
30-061 !short circuit on
Upoe Port SLMC
on
Short circuit in
base station line.
Check lines.
Replace base stations.
30-062 !short circuit on
Upoe Port SLMC
off
Short circuit in
base station line
has been correct-
ed.
None
Error Class 32 – Messages Concerning IVM (HiPath Xpressions Compact) and EVM
(Entry Voice Mail)
32-000 !Configuration link
up
32-001 !Configuration link
down
32-008 !TIMEOUT during
server-msg
32-010 !IVM: Exception
(unexpected er-
ror)
IVM: An unexpect-
ed error has oc-
curred.
Set up an IVM trace.
32-011 !IVM: SW-error
IVM: A software er-
ror has occurred.
Set up an IVM trace.
Upgrade IVM if necessary.
32-013 !IVM: HD assign-
ment of memory
space 80%
IVM: 80% of hard
disk used.
Search IVM statistics for
mailboxes with too many
undeleted messages.
32-014 !IVM: HD full
IVM: Hard disk is
full.
Search IVM statistics for
mailboxes with too many
undeleted messages.
32-015 !IVM: Mailbox not
available
IVM: Mailbox is not
available.
Check whether the sub-
scriber in question is avail-
able in the event log.
Set up IVM system mail-
box if necessary.
Table 12-7
HiPath 3000 Class B Error Messages
No. HiPath
3000/
5000 Manager E:
Event Log Entry
Meaning
Required Measures
Note
Summary of Contents for HiPath 3000 Series