System Data
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
2-44
HiPath 3000/5000 V9, Service documentation
sysdat.fm
System-Specific Capacity Limits for HiPath 3000, HiPath 5000
HG 1500 boards
8
3
3
1 (2
24
)
1 (2
)
–
Gateway channels to the system
128
48
48
16
16
–
1
https:/
/enterprise-businessarea.siemens-enterprise.com/productinfo/document/9fTFkWdA76U_/Hi-
Path%203000%20V8%20Planungsanleitung%20Performance%20Calculation%20Tool.xls
).
2
Only configurations that do not exceed this limit will be supported.
3
Up to 96 stations can be TDM stations.
4
Up to 61 of the 96 stations can be TDM stations (4xanalog T/R + 1xU
P0/E
+ 7xBS/32xHiPath Cordless Office stations at
the central board + 3xSLU8R or 3x8SLAR or 3xSLAD8R).
5
Up to 41 of the 96 stations can be TDM stations (4xa/b + 5xU
P0/E
+ 3xBS/16xHiPath Cordless Office stations at the central
board + 1x16SLA).
6
Up to 33 of the 96 stations can be TDM stations (4xa/b + 5xU
P0/E
+ 3xBS/16xHiPath Cordless Office stations at the central
board + 1xSLU8R or 1x8SLAR or 1xSLAD8R).
7
These are administrative capacity limits.
8
Due to the power consumption of HG 1500, a UPSC-D must be used.
9
Due to the power consumption of HG 1500, a UPSC-DR must be used.
10 If the total number of U
P0/E
stations, analog stations and additional stations connected using an adapter is greater than 72,
an external power supply unit (Powerbox PB3000 with LUNA2) must be used.
11 4xa/b + 1xU
P0/E
+ 7xBS/32xHiPath Cordless Office stations at the central board + 5xSLU8R or 5x8SLAR or 5xSLAD8R.
12 4xa/b + 5xU
P0/E
+ 3xBS/16xHiPath Cordless Office stations at the central board + 2x16SLA.
13 4xa/b + 5xU
P0/E
+ 3xBS/16xHiPath Cordless Office stations at the central board + 2xSLU8R or 2x8SLAR or 2xSLAD8R.
14 4xa/b at the central board + 5x8SLAR or 5xSLAD8.
15 4xa/b at the central board + 2x16SLA.
16 4xa/b at the central board + 2x8SLAR or 2xSLAD8.
17 8xU
P0/E
at the central board + 1xSLMO24.
18 8xU
P0/E
at the central board + 5xSLU8R.
19 8xU
P0/E
at the central board + 2xSLU8.
20 8xU
P0/E
at the central board + 2xSLU8R.
21 If the total number of U
P0/E
stations and additional stations connected using an adapter is greater than 24, UPSC-D/UPSC-
DR must be used.
22 Due to the 5-V power supply unit, one SLC16N and a maximum of two HG 1500 V3.0 boards can be used.
23 64 HiPath Cordless Office stations at the SLC16N or 32 HiPath Cordless Office stations at the central board.
24 The system may be configured with two HG 1500 boards if PDM1 is not used.
Table 2-26
HiPath 3000/5000 - System-Specific Capacity Limits (Maximum Configuration)
System
HiPath
3800
1
HiPath
3550
HiPath
3500
HiPath
3350
HiPath
3300
HiPath
Com-
Scendo
Service
Summary of Contents for HiPath 3000 Series