System Data
Interface-to-Interface Ranges
2.7
Interface-to-Interface Ranges
Telephone interface-to-interface ranges
Trunk connection and CorNet N/CorNet NQ ranges
The table below provides the maximum cable lengths for direct trunk connection and direct Cor-
Net N/CorNet NQ Direct Wiring. The values apply to ideal conditions, which means there can
be no joints, etc. The real conditions must be measured on-site.
Table 2-60
Telephone Interface-to-Interface Ranges (with J-Y (ST) 2x2x0.6, 0.6 mm di-
ameter)
Telephone Interfaces
Range in m
Loop resistance
in ohms
ISDN-S
0
point-to-point
< 600
156
ISDN S
0
extended bus connection
< 400
104
ISDN S
0
bus connection
1
1
Board-specific
< 60
for the HiPath 3800 board STMD3
(Q2217)
< 120
for all other S
0
boards
21
ISDN-S
0
wall outlet to terminal
< 10
–
Analog users
< 2000
520
U
P0/E
exchange to host (master)
< 1000
230
U
P0/E
host to client (master/slave)
< 100
23
Table 2-61
Cable Lengths for Trunk Connection and Direct CorNet N/CorNet NQ Direct
Wiring
Inter-
face
Cable
Diameter
Attenuation
per km
Max. Cable
Length
S
0
ICCS cable
J-2Y(ST)Y4x2x0.51 LG ICCS
Data5
0.51 mm
7,5 dB
at 96 kHz
800 m
Installation cable
J-2Y(ST)Y 10x2x0.6 ST III BD
0.6 mm
6.0 dB
at 96 kHz
1000 m
S
2M
A-2Y0F(L)2Y
10x2x0.6 (full PE
insulation, filled)
0.6 mm
17 dB
at 1 MHz
350 m