Runtime Actions
SECTION 9 Animation
152
A colour can be selected by clicking on one of the palette colours. This
becomes the selected colour, and is denoted as such in the Selected Colour:
field. Alternatively, a colour can be selected by specifying a colour name or
number in the Colour Name: field. The selected colour within the palette can
be mixed by using the red, blue and green scroll bars to the right of the palette.
Each colour in the colour palette is numbered from 0 to 65, number 0 located
in the top-left position of the palette, with numbers reading consecutively
across, then down, with colour number 65 in the bottom-right position of the
palette. Additionally, colour numbers 0 to 19 are named - for instance, colour
number 0 is named "black".
Colours 0 to 15 inclusive are system colours and cannot be mixed. Although it
is possible to mix new colours using the scroll bars, it is not possible to save
such changes from this palette. To ensure new colours are saved, use General
Settings from the Project menu.
Note:
Using a 16 colour-based screen resolution (consult the Microsoft Windows
documentation for further information) colours 16 to 65 are dithered from the
sixteen base colours. Higher colour-based resolutions are not dithered.
Summary of Contents for CX-Supervisor
Page 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Page 3: ...Copyright Notice 2...
Page 16: ...15...
Page 17: ...16...
Page 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Page 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Page 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Page 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Page 181: ...Data Logging SECTION 11 Data Logging 180...
Page 201: ...Examples SECTION 12 Databases 200...
Page 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Page 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Page 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Page 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Page 271: ...Data Logging SECTION 20 Best Practices 270...
Page 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Page 277: ...Appendix B Frequently Asked Questions 276...
Page 296: ...Appendix B Frequently Asked Questions 295...
Page 297: ...Appendix B Frequently Asked Questions 296...
Page 298: ...Appendix B Frequently Asked Questions 297...
Page 299: ...Appendix B Frequently Asked Questions 298...
Page 333: ...Revision history 332...