Using CX-Supervisor with OPC Servers SECTION 17 Using CX-Supervisor as an OPC
249
OPC Communication Control Settings
Name: - This is the name of the selected communications control. The
default name for the first control is
OMRONCXOPCCommunicationsControl. For each additional control
added the number increments by one.
Computer Name
: - This shows the system name for the computer with
the OPC server. If the server is on the same computer as CX-Supervisor,
set to '(Local)'. If the OPC server is on a remote computer click the Show
All button and select the correct name from the list. If you cannot identify
the PC in the list contact your system administrator.
Server Name
: - This shows the names of the OPC Version 2 compliant
servers installed on the specified computer. Make your selection from the
drop down list. Clicking the Info button opens the Server Status
Information dialog box for the selected server, check the information is
correct and click the OK button.
Project File
: - This is the name of the current Project file which stores the
setup of the OPC items. If no name is shown or it is incorrect click the New
or Open button as appropriate.
Clicking the Open… button opens the Open Project dialog box from where
you can navigate to the project file you wish to open. If you want to create
a new file click the New… button to open the Create Project dialog box. In
the Create Project dialog box navigate to the directory in which you want
to create your new file and enter your File Name. Select the appropriate
file type (Save as type - i.e. File Name.opc) and click the Save button.
(B) GROUPS TAB
The groups within the selected project file are listed. A Group is made up
of one or more items (data points) that share a common update, rate
enabling them to be controlled as a single entity. For example you could
create any number of groups each containing Items that have the same
update rate.
There is no limit to the number of groups you can have in a Project File
and each group can contain any number or type of Items (data points)
provided they have the same update rate.
Note:
If the server is not shown in the drop down list, the server may not be fully
OPC version 2 compliant. Check the server documentation.
Note:
A Project File name can not be entered from the keyboard. File names
can only be entered by using the New or Open buttons.
Summary of Contents for CX-Supervisor
Page 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Page 3: ...Copyright Notice 2...
Page 16: ...15...
Page 17: ...16...
Page 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Page 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Page 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Page 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Page 181: ...Data Logging SECTION 11 Data Logging 180...
Page 201: ...Examples SECTION 12 Databases 200...
Page 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Page 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Page 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Page 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Page 271: ...Data Logging SECTION 20 Best Practices 270...
Page 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Page 277: ...Appendix B Frequently Asked Questions 276...
Page 296: ...Appendix B Frequently Asked Questions 295...
Page 297: ...Appendix B Frequently Asked Questions 296...
Page 298: ...Appendix B Frequently Asked Questions 297...
Page 299: ...Appendix B Frequently Asked Questions 298...
Page 333: ...Revision history 332...