Runtime Actions
SECTION 9 Animation
135
9-3-5
Script Completion
When script entry or script modification is complete, click the OK button. To
abort the Script Editor prior to completing the task, click the Cancel button.
If there is an error in the script, the Compilation Error(s) dialog box opens.
In this example, the error is caused by a spurious 'ENDIF'.
This dialog box informs the user where an error has occurred and its type. If
necessary, use the scroll bars to see the whole error message. Click the
OK
button to remove the Compilation Error(s) dialog box and return to the Script
Editor to fix the error.
9-3-6
Horizontal Move
Objects can be animated by moving either left or right. This is specified using
the Move (Horizontal) dialog box.
To access the Move (Horizontal) dialog box to add an action, select Move
(Horizontal) from the animation list and click the Add Action button. To access
the Move (Horizontal) dialog box to modify an action, select Move (Horizontal)
from the animation list and click the Modify Action button. Refer to the Script
Reference chapter 10, Objects, for a list of the objects to which this action is
applicable.
On selection of the Move (Horizontal) action, the Move (Horizontal) dialog box
opens:
To define the animation, an expression consisting of a number of operators
and operands (which may be based on the status of a point) must be entered
in the Expression: field. The boundaries in which the object moves are
inserted into the Active Expression Range/Required Position: fields. The
Maximum Offset specifies the number of pixels to the right (from its initial
position) that the object moves when the result of the expression reaches the
Maximum Value. The Minimum Offset specifies the number of pixels to the left
(from its initial position) that the object moves, when the result of the
Summary of Contents for CX-Supervisor
Page 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Page 3: ...Copyright Notice 2...
Page 16: ...15...
Page 17: ...16...
Page 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Page 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Page 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Page 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Page 181: ...Data Logging SECTION 11 Data Logging 180...
Page 201: ...Examples SECTION 12 Databases 200...
Page 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Page 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Page 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Page 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Page 271: ...Data Logging SECTION 20 Best Practices 270...
Page 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Page 277: ...Appendix B Frequently Asked Questions 276...
Page 296: ...Appendix B Frequently Asked Questions 295...
Page 297: ...Appendix B Frequently Asked Questions 296...
Page 298: ...Appendix B Frequently Asked Questions 297...
Page 299: ...Appendix B Frequently Asked Questions 298...
Page 333: ...Revision history 332...