![background image](http://html1.mh-extra.com/html/omron/cx-supervisor/cx-supervisor_user-manual_744211101.webp)
Runtime Security
SECTION 6 Projects
100
A user can detach from specialised user privileges by logging out. Access is
again dependant on the application. There is no dialog box associated with
logout; once logout is activated privileges are immediately discontinued. While
one user is logged in, it is possible for a different user to log in, as prior to
login, the current user is automatically logged-out by CX-Supervisor.
A user with the designer privilege can further amend the user configuration in
the runtime environment using a similar dialog box to the development
environment's Configured Users dialog box. As well as typing a password,
verification of the password is required, and both fields are disguised by a '*'
symbol. This is so that a new user can apply their own password, and that only
they know the password. Verification is required to ensure the password was
typed correctly in the first instance.
6-11-2 Linking CX-Supervisor Users With Windows Users
In CX-Supervisor v3.1, a new feature was added to the Security System that
allows CX-Supervisor users to be linked with Windows users, using the ‘Use
Windows Login Credentials’ option shown in the ‘Configured Users’ dialog
above. This functionality is associated with the CFR functionality and provides
a greater level of security protection, including password expiration etc., by
making use of the Windows security features.
6-11-3 Menu Option Access Levels
To open the
Menu Option Access Levels
dialog box select
Menu Option
Access Levels
from the
Runtime Security
menu
As well as a context-sensitive floating menu for the development environment,
there is a floating menu for the runtime environment which is configurable in
the development environment. It is possible to select the operations to be on
the runtime floating menu, by clicking the relevant setting across the three tabs
General, Utilities and Communications. It is also possible to assign a level of
user privilege to the menu, so each level of user sees a different floating
menu. This is achieved by selecting a user privilege from the relative drop
down list. The Communications tab permits the activation of CX-Server
Summary of Contents for CX-Supervisor
Page 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Page 3: ...Copyright Notice 2...
Page 16: ...15...
Page 17: ...16...
Page 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Page 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Page 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Page 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Page 181: ...Data Logging SECTION 11 Data Logging 180...
Page 201: ...Examples SECTION 12 Databases 200...
Page 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Page 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Page 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Page 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Page 271: ...Data Logging SECTION 20 Best Practices 270...
Page 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Page 277: ...Appendix B Frequently Asked Questions 276...
Page 296: ...Appendix B Frequently Asked Questions 295...
Page 297: ...Appendix B Frequently Asked Questions 296...
Page 298: ...Appendix B Frequently Asked Questions 297...
Page 299: ...Appendix B Frequently Asked Questions 298...
Page 333: ...Revision history 332...