Compiling and Running a Project
SECTION 6 Projects
101
components such as the PLC Data Trace and PLC Memory Card components.
Refer to the CX-Server Reference Manual for further information on CX-
Server components.
On completion, click the
OK
button to accept changes or the
Cancel
button to
abort.
6-11-4 Exit Level
An additional security measure can be applied by selecting Exit Level from the
Runtime Security menu. The Exit Level dialog box opens:
The dialog box allows a specific privilege to be applied to exiting the runtime
application. Select a user privilege from the drop down list and click the OK
button to confirm the setting or the Cancel button to abort.
6-12
Compiling and Running a Project
When a project is running it cannot be edited. CX-Supervisor runs projects
under the CX-Supervisor runtime environment.
6-12-1 Building a Project
To create the CX-Supervisor runtime project click the
button. This compiles
the projects and pages into a CX-Supervisor runtime file (.sr2).
6-12-1-1 Rebuild All
The Rebuild All option on the Project menu causes the entire application to be
re-compiled. Together with the Analyse Application feature, this can be used to
validate your project.
CX-Supervisor checks application integrity whenever the application is
compiled or run and warns that a full rebuild may be necessary. When the
'Rebuild All' operation is carried out all errors and warnings will be reported in
the output window and double clicking on a specific error will usually take you
directly to the source of that error. During a full rebuild, all pages that are
successfully recompiled will optionally be saved automatically. All pages that
fail to recompile are not saved. This means that it will still be possible to build
and run the application after a 'Rebuild All' has been carried out if it was
possible to build it and run it before the 'Rebuild All' operation.
Note: the 'rebuild all recommended' warning message can be disabled via the
Editing Preferences dialog box.
Due to a change of syntax in a previous release of CX-Supervisor the 'Display'
and 'Close' script functions (CX-Supervisor Script) will NOT compile if they use
the old syntax (e.g. Display "Page"). They must be changed to the new syntax
(e.g. Display("Page")). If an application with these issues is not recompiled
then it will continue to run correctly in the Runtime.
6-12-2 Running a Project
To run the current project, click the
button. This will automatically build the
project if required.
Summary of Contents for CX-Supervisor
Page 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Page 3: ...Copyright Notice 2...
Page 16: ...15...
Page 17: ...16...
Page 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Page 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Page 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Page 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Page 181: ...Data Logging SECTION 11 Data Logging 180...
Page 201: ...Examples SECTION 12 Databases 200...
Page 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Page 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Page 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Page 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Page 271: ...Data Logging SECTION 20 Best Practices 270...
Page 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Page 277: ...Appendix B Frequently Asked Questions 276...
Page 296: ...Appendix B Frequently Asked Questions 295...
Page 297: ...Appendix B Frequently Asked Questions 296...
Page 298: ...Appendix B Frequently Asked Questions 297...
Page 299: ...Appendix B Frequently Asked Questions 298...
Page 333: ...Revision history 332...