Appendix B Frequently Asked Questions
282
•
Can I run CX-Supervisor Runtime as a restricted Windows User?
CX-Supervisor (and CX-Server) require Administrator rights to be
installed on a computer, but other users can then run the software. The
runtime will run without problems as a Standard User (member of Power
Users group) and will run as a Restricted User (member of Users Group)
although will show errors when trying to update the registry.
To avoid these errors specific registry access can be provided by an
Administrator to the following registry keys:
•
HKEY_CLASSES_ROOT\CLSID\{0002D780-0000-0000-C000-
000000000046}
•
HKEY_CLASSES_ROOT\CLSID\{0002D781-0000-0000-C000-
000000000046}
•
HKEY_CLASSES_ROOT\CX-Supervisor.Application
•
HKEY_CLASSES_ROOT\CX-Supervisor.Project
•
Can I use CX-Simulator with CX-Supervisor?
Integrated Simulation can be used to automatically launch and use CX-
Simulator. See 'Compiling and Running a Project' for more details.
Omron's CX-Simulator virtual PLC can also be manually configured for
use with CX-Supervisor. To achieve this follow these steps:
1.Start CX-Simulator from the windows Start menu.
2.Select 'Create New PLC'
3.Select the required PLC Type
4.No need to register I/O ---> Next
5.Keep default Virtual Comms Unit ---> Next
6.Keep default Comm Port ---> Next
Summary of Contents for CX-Supervisor
Page 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Page 3: ...Copyright Notice 2...
Page 16: ...15...
Page 17: ...16...
Page 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Page 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Page 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Page 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Page 181: ...Data Logging SECTION 11 Data Logging 180...
Page 201: ...Examples SECTION 12 Databases 200...
Page 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Page 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Page 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Page 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Page 271: ...Data Logging SECTION 20 Best Practices 270...
Page 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Page 277: ...Appendix B Frequently Asked Questions 276...
Page 296: ...Appendix B Frequently Asked Questions 295...
Page 297: ...Appendix B Frequently Asked Questions 296...
Page 298: ...Appendix B Frequently Asked Questions 297...
Page 299: ...Appendix B Frequently Asked Questions 298...
Page 333: ...Revision history 332...