Trajexia Devices
SECTION 6 Projects
86
For further information about Fins Gateway, including instructions on
configuring Fins Gateway, refer to the online Help system that is installed with
Fins Gateway (Fins Gateway is provided on the CX-Supervisor CD).
6-9
Trajexia Devices
Trajexia devices are part of Omron's range of Motion Controllers. Points are
addressed in a similar fashion to points on a PLC. To read or write table
memory use the prefix "T" followed by the address. For example to access
address 1000 in table memory, use the data location "T1000". VR memory is
addressed in a similar fashion, but with the prefix "VR". For example to read
address 500, the format is "VR500". If a point in VR memory is configured as
type "IEEE float" then all values will be rounded to integers, since the
communication protocol doesn't currently support floating point addressing of
this memory area.
The following example describes how to read and write Trajexia (TJ1) data in
a CX-Supervisor application. It assumes that both CX-Supervisor and the TJ1
driver are already installed on a user's PC.
Preparation:
Connect a TJ1 motion
controller to an Ethernet
network.
Setting up the points
1. Start
CX-Supervisor
.
2. Either create a new CX-Supervisor project, or open an existing project.
3. Use the toolbar to select the "Device Setup" dialog box and press the
Add…
button.
4. Select "TJ1 Device" as the device type and give the device an appropriate
name. A network of "Ethernet" should be automatically selected.
5. Click the
Settings
button next to "Device Type", and then select the model
of the device you will be using.
Summary of Contents for CX-Supervisor
Page 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Page 3: ...Copyright Notice 2...
Page 16: ...15...
Page 17: ...16...
Page 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Page 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Page 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Page 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Page 181: ...Data Logging SECTION 11 Data Logging 180...
Page 201: ...Examples SECTION 12 Databases 200...
Page 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Page 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Page 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Page 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Page 271: ...Data Logging SECTION 20 Best Practices 270...
Page 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Page 277: ...Appendix B Frequently Asked Questions 276...
Page 296: ...Appendix B Frequently Asked Questions 295...
Page 297: ...Appendix B Frequently Asked Questions 296...
Page 298: ...Appendix B Frequently Asked Questions 297...
Page 299: ...Appendix B Frequently Asked Questions 298...
Page 333: ...Revision history 332...