Creating a Point
SECTION 3 Points
42
The Array Size: field specifies the number of data values associated with the
point. A value greater than 1 allows the point to be treated as an array. For
more detail on array points and their uses see Optimisation of PLC
Communications.
The PLC Attributes dialog box takes on a slightly different appearance if the
point type is text, showing the number of characters which start at the
specified data location:
3-4-9
Data Transfer Actions When Opening a PLC
The type of data transfer action for the selected PLC can be specified by
selection of the appropriate setting. Options for Input and Input/Output points
are Always Update Point Value and Only Update Point Value When On
Display. Options for an Output point are Write Value, Read Value and No Data
Transfer.
3-4-10 Conversion Attributes
The minimum and maximum PLC value and the application of a conversion
factor is specified in the Conversion Attributes: fields (these fields are not
applicable for Boolean and text points).
Conversion Attributes can be used to convert in a linear fashion between a
value in a PLC and the point range. For example, if the possible range in the
PLC is 0 to 1000, and the point range is 0 to 100, then a PLC value of 500
would correspond to a point value of 50. The conversion would be performed
just before the data is sent to the PLC, or immediately upon receipt of it from
the PLC.
On completion of the PLC configuration connection, click the OK button to
continue, or the Cancel button to abort. Click the Add PLC button to create a
new PLC connection. Information relating to the selection of this button is
described in chapter 6 Projects, Device Configuration.
3-4-11 Advanced Point Settings
Advanced settings can be applied to a new point, by clicking the
Advanced
button in the
Add Point
dialog box. This results in the
Advanced Point
Settings
dialog box being displayed.
In order to access a CX-Supervisor point value via OLE2 Automation, it must
be given OLE Read or OLE Write access. The scope of the access can be
defined by checking the appropriate setting in the OLE Access.
Summary of Contents for CX-Supervisor
Page 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Page 3: ...Copyright Notice 2...
Page 16: ...15...
Page 17: ...16...
Page 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Page 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Page 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Page 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Page 181: ...Data Logging SECTION 11 Data Logging 180...
Page 201: ...Examples SECTION 12 Databases 200...
Page 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Page 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Page 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Page 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Page 271: ...Data Logging SECTION 20 Best Practices 270...
Page 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Page 277: ...Appendix B Frequently Asked Questions 276...
Page 296: ...Appendix B Frequently Asked Questions 295...
Page 297: ...Appendix B Frequently Asked Questions 296...
Page 298: ...Appendix B Frequently Asked Questions 297...
Page 299: ...Appendix B Frequently Asked Questions 298...
Page 333: ...Revision history 332...