Appendix F Obsolete Features
309
Appendix F
Obsolete Features
This appendix provides a summary of features that are obsolete and have
been removed from the standard documentation. Details are included here to
assist maintaining old projects still using these features. These features
should not be used in development of new solutions as it is likely support for
the following features may and will be removed from the next or future
releases.
F.1 Windows 98, Windows ME, Windows NT
This product no longer installs on Windows 98, ME or NT. It is recommended
to upgrade to Windows 2000 or Windows XP Professional.
F.2 Configuring a OPC/DCOM Client PC running Windows 98 or
Me
1, 2, 3…
1. Ensure File and Printer sharing is enabled by selecting Network from the
Control Panel. Add a service and click either "File and print sharing for
Microsoft Networks" or "File and print sharing for Netware Networks" as
appropriate.
2. Start DCOMCNFG.EXE e.g. by selecting RUN from the Start button. The
default location is C:\WINDOWS\SYSTEM.
3. View the Default Properties tab. Ensure that the Enable Distributed COM
on this computer is checked.
A CX-Supervisor Client running on Windows 98 or ME also requires the
Microsoft Remote Registry network service to be installed with the operating
system and correctly configured on both the server and client machine. To
check: start the Control Panel and view the Network settings. In the list of
network components, look for Microsoft Remote Registry. If it does not exist,
follow these steps to add it.
1, 2, 3…
1. In the Network settings, ensure User-level access control is selected on
the Access Control tab.
2. From the Configuration tab, click Add to add a Network component.
Choose Service from the type list and click Add.
3. Click Have Disk… and browse your Windows CD. Select the path
(\Admin\Nettods\remotReg) for Win95 CD or
(\Tools\ResKit\NetAdmin\RemotReg) for Win98 and select regsrv.inf.
4. Follow the screen prompts to complete installation and reboot if
necessary.
5. On the server machine, select Passwords from the Control Panel.
6. Ensure the Enable remote administration of this server option is checked
7. Add all required user ids to the Administrators list by clicking Add…
Note:
Windows ME no longer includes the Microsoft Remote Registry network
service on the product CD but this can still be installed and used from any
Windows 95 or Windows 98 CD ROM using the above steps.
Summary of Contents for CX-Supervisor
Page 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Page 3: ...Copyright Notice 2...
Page 16: ...15...
Page 17: ...16...
Page 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Page 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Page 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Page 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Page 181: ...Data Logging SECTION 11 Data Logging 180...
Page 201: ...Examples SECTION 12 Databases 200...
Page 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Page 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Page 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Page 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Page 271: ...Data Logging SECTION 20 Best Practices 270...
Page 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Page 277: ...Appendix B Frequently Asked Questions 276...
Page 296: ...Appendix B Frequently Asked Questions 295...
Page 297: ...Appendix B Frequently Asked Questions 296...
Page 298: ...Appendix B Frequently Asked Questions 297...
Page 299: ...Appendix B Frequently Asked Questions 298...
Page 333: ...Revision history 332...