6-10-2-9 Point Substitution Settings
The enclosing characters associated with a report can be changed via the
Point Substitution Settings dialog box. When set, these characters must be
fixed for all reports generated by the project. Select
Runtime Settings
from
the
Projects
menu, followed by
Point Substitution Settings
, the Point
Substitution Settings dialog box opens.
Supply enclosing characters in the Opening Characters: field and Closing
Characters: field. Click the
OK
button to accept the settings, or the Cancel
button to abort the operation.
6-10-2-10Advanced Settings
To open the Advanced Settings dialog box select Advanced Settings from the
Runtime Settings
menu:
Click the settings to enable/disable Internal Communication Optimisations and
Communication 'Packet' Optimisations.
Bad Quality values, and results of calculations using bad quality values can be
shown as '#' characters. This could indicate a communication failure, or Bad
Quality status in an OPC Server.
If you may need to option to edit the PLC settings in the runtime without
recompiling in the developer then untick the "Embed CX-Server Project within
CX-Supervisor .SR2 file" option. This is useful for example if it is possible the
Summary of Contents for CX-Supervisor
Page 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Page 3: ...Copyright Notice 2...
Page 16: ...15...
Page 17: ...16...
Page 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Page 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Page 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Page 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Page 181: ...Data Logging SECTION 11 Data Logging 180...
Page 201: ...Examples SECTION 12 Databases 200...
Page 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Page 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Page 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Page 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Page 271: ...Data Logging SECTION 20 Best Practices 270...
Page 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Page 277: ...Appendix B Frequently Asked Questions 276...
Page 296: ...Appendix B Frequently Asked Questions 295...
Page 297: ...Appendix B Frequently Asked Questions 296...
Page 298: ...Appendix B Frequently Asked Questions 297...
Page 299: ...Appendix B Frequently Asked Questions 298...
Page 333: ...Revision history 332...