![Okuma OSP-P200L Programming Manual Download Page 308](http://html1.mh-extra.com/html/okuma/osp-p200l/osp-p200l_programming-manual_3667818308.webp)
5238-E P-295
SECTION 12 USER TASK
The concept is illustrated in the figure below.
LE33013R0301400380003
[Program examples]
Example 1. Program using READ/WRITE statements and GET/PUT statements
LE33013R0301400380004
Common
variable
System
variable
Local
variable
Input/output
variable
GET
PUT
READ
WRITE
Read area
Write area
Programming
CN0
CN1
CN4
RS232C
interface
External
device,
Puncher,
Printer,
etc.
N1
N2
N3
N4
N5
N6
N7
N8
N9
N10
N11
READ 0
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
Data is read from CN0:.
GET
GET
lF [V1 EQ 0] N11
GET
GET
GET
GET
GET
GET
,
,
,
10
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
Message (a) (10 letters) is skipped.
V 1, 1
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
11th letter is read into V1.
9
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
Message (b) (9 letters) is skipped.
V2 ,2
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
21st and 22nd letters are read into V2.
VTOFX [V2], 5
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
27th to 31st letters are read into tool offset data.
4
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
Message (d) (4 letters) is skipped.
VTOFZ [V2]
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
36th to 40th letters are read into tool offset data.
4
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
Message (c) (4 letters) is skipped.