![Okuma OSP-P200L Programming Manual Download Page 298](http://html1.mh-extra.com/html/okuma/osp-p200l/osp-p200l_programming-manual_3667818298.webp)
5238-E P-285
SECTION 12 USER TASK
Reading an output status
Procedure :
1
Search for the I/O signal that you want to refer to from the I/O bit table, and check its label.
If, for example, you want to check "Machine lock", find the label "opMLCK".
2
Search for "opMLCK" with the I/O monitor in the same manner as in reading an input status.
3
When the searching is completed, the following screen appears.
The address QX0513.6 indicated at L_addr shows that the logical address is 513 and its bit
number is 6. Specify the VORD command by entering the value obtained by subtracting 512
from the logical address. That is, you can read the machine lock status by specifying
VORD[0016].
LE33013R0301400260005