NORDAC SK 200E Manual
196
Subject to technical alterations BU
0200
GB
Parameter
Setting value / Description / Note
Device
Supervisor
Parameter
set
P748
Status CANopen
(system bus status)
Displays the system bus status.
Bit 0:
Bit 1:
Bit 2:
Bit 3:
Bit 4:
Bit 5:
Bit 6:
Bit 7:
Bit 8:
Bit 9:
Bit 10:
24V Bus supply voltage
CANbus in "Bus Warning" status
CANbus in "Bus Off" status
System bus
→
Bus module online (field bus module, e.g.: SK xU4-PBR)
System bus
→
Additional module 1 online (I/O - module, e.g.: SK xU4-IOE)
System bus
→
Additional module 2 online (I/O - module, e.g.: SK xU4-IOE)
The protocol of the CAN module is 0 = CAN / 1 = CANopen
vacant
"Bootsup Message" sent
CANopen NMT State
CANopen NMT State
CANopen NMT State
Bit 10
Bit 9
Stopped
Pre-Operational
Operational
0
0
1
0
1
0
0000 ... FFFF
(hex)
or
0 ... 65535
(dec)
P749 Status
DIP
switches
This setting displays the actual setting of the FI DIP switches (Section 5.1.1).
0000 ... 00FF
(hex)
or
0 ... 255
(dec)
Bit 0:
Bit 1:
Bit 2:
Bit 3:
Bit 4:
Bit 5:
Bit 6:
Bit 7:
DIP switch 1
DIP switch 2
DIP switch 3
DIP switch 4
DIP switch 5
DIP switch 6
DIP switch 7
DIP switch 8
Summary of Contents for SK 200E Series
Page 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Page 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Page 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Page 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Page 263: ...10 Keyword index BU 0200 GB 263...
Page 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Page 265: ...The Nordac SK 200E is available to order from www inverterdrive com...