6 Parameterisation
BU 0200 GB
Subject to technical alterations
165
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
P412 Nom
inal
val
ue
process
c
on
tr
o
l
ler
S
P
-10.0 ... 10.0 V
{ 5.0 }
Fixed specification of a setpoint for the process controller that will only occasionally be altered.
Only with P400 = 6 or 7 (PID process controller). Further technical details can be found in
Section 9.2.
P413
PI control P-comp
onent
S
P
0.0 ... 400.0 %
{ 10.0 }
This parameter is only effective when the function PI controller actual frequency is selected.
The P-component of the PI controller determines the frequency jump if there is a control
deviation based on the control difference.
For example: At a setting of P413 = 10% and a control difference of 50%, 5% is added to the
actual setpoint.
P414
PI control I-comp
onent
S
P
0.0 ... 3000.0 %/s
{ 10.0 }
This parameter is only effective when the function PI controller actual frequency is selected.
In case of a control deviation, the I-component of the PI controller determines the frequency
change, dependent on time.
Note:
In contrast to other NORD series, parameter P414 is smaller by a factor of 100
(Reason: better setting ability with small I-components).
P415 Process
control
ler
control limit
S
P
0 ... 400.0 %
{ 10.0 }
This parameter is only effective when the function
PI process controller
is selected. This
determines the control limit (%) after the PI controller.
For further details, see Section 9.2.
P416
Ramp time, PI setpoint
value
S
P
0.00 ... 99.99 s
{ 2.00 }
This parameter is only effective when the function PI process controller is selected.
Ramp for PI setpoint
P417
[-01]
[-02]
Offset, analog
output
1
S
P
-10.0 ... 10.0 V
{ all 0.0 }
[-01] =
First IOE,
AOUT of the first I/O extension (SK xU4-IOE)
[-02] =
Second IOE,
AOUT of the second I/O extension (SK xU4-IOE)
... only with
SK CU4-IOE or
SK TU4-IOE
In the analog output function an offset can be entered to simplify the processing of the analog
signal in other equipment.
If the analog output has been programmed with a digital function, then the difference between
the switch-on point and the switch-off point can be set in this parameter (hysteresis).
P418
[-01]
[-02]
Func
tion,
analog
output
1
S
P
0 ... 33
{ all 0 }
[-01] =
First IOE,
AOUT of the first I/O extension (SK xU4-IOE)
[-02] =
Second IOE,
AOUT of the second I/O extension (SK xU4-IOE)
Summary of Contents for SK 200E Series
Page 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Page 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Page 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Page 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Page 263: ...10 Keyword index BU 0200 GB 263...
Page 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Page 265: ...The Nordac SK 200E is available to order from www inverterdrive com...