8 Technical data
BU 0200 GB
Subject to technical alterations
239
Size 1 - 400V mains
Device type:
SK 2xxE…
-550-340-A
-750-340-A
-111-340-A
-151-340-A
-221-340-A
380V
0.55 kW
0.75 kW
1.1 kW
1.5 kW
2.2 kW
Rated motor power
(4-pole standard
motor)
460 …
480V
¾ hp
1 hp
1½ hp
2 hp
3 hp
FLA
3 AC
min. mains fuse
[A]
1.6 2.2 2.9 3.7
5.7
RK5 or faster
fuses, min
230/400V
5.0 A
5.0 A
10 A
10 A
10 A
Bussmann FRS-R-5
FRS-R-5
FRS-R-10 FRS-R-10
FRS-R-10
Max. mains
fuse
Circuit breaker*
min. 230/400V
5.0 A
5.0 A
10 A
10 A
10 A
Rated output
current at 40°C
Motor mounted
Wall mounting
1.7A
(45°C)
1.7A
(45°C)
2.3A
(45°C)
2.3A
(45°C)
3.1A
(45°C)
3.1A
(45°C)
4.0A
(45°C)
3.3A
5.5A
(45°C)
3.3A
*Circuit Breaker (inverse time trip type) as per UL489
Size 2 / 3 - 400V mains
Device type:
SK 2xxE…
-301-340-A
-401-340-A
-551-340-A
-751-340-A
380V
3.0 kW
4.0 kW
5.5 kW
7.5 kW
Rated motor power
(4-pole standard
motor)
460 …
480V
4 hp
5 hp
7½ hp
10 hp
FLA
3 AC
min. mains fuse
[A] 7.7
9.6
12.7
16.6
RK5 or faster
fuses, min
230/400V
10 A
30 A
30 A
30 A
Bussmann FRS-R-10
FRS-R-30 FRS-R-30
FRS-R-30
Max. mains
fuse
Circuit breaker*
min. 230/400V
10 A
25 A
25 A
25 A
Rated output
current at 40°C
Motor mounted
Wall mounting
7.5A
(45°C)
4.0A
9.5A
(41 )
4.9A
12.5A
(45°C)
6.9A
16.0A
(43 )
7.9A
*Circuit Breaker (inverse time trip type) as per UL489
Summary of Contents for SK 200E Series
Page 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Page 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Page 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Page 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Page 263: ...10 Keyword index BU 0200 GB 263...
Page 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Page 265: ...The Nordac SK 200E is available to order from www inverterdrive com...