1 General
BU 0200 GB
Subject to technical alterations
9
1 General information
The NORDAC SK 200E is based on the tried and tested NORD platform. These devices feature a compact
design with optimum control characteristics.
These devices are provided with sensorless vector current control which in combination with asynchronous
three-phase motor types constantly ensures an optimised voltage-to-frequency ratio. This has the following
significance for the drive: Peak start-up and overload torques at constant speed.
This series of devices can be adapted to individual requirements by means of extension modules.
Due to the numerous setting options, these inverters are capable of operating all three-phase motors. The
power range is from
0.25kW to 7.5kW
with an integrated mains filter.
This manual is based on the device software V1.2 R0 (see P707) of the SK 200E. If the frequency inverter
used has a different version, this may lead to some differences. If necessary, you can download the current
manual from the Internet (
http://www.nord.com/
).
For the SK 215E/225E/235E there are additional descriptions for functional safety
(BU 0230), the integrated AS interface (BU 0200, Section 5.4) and the positioning system (BU 0210). These
contain all the necessary additional information for start-up.
If a bus system is used for communication, a corresponding description (e.g. BU 0220 für PROFIBUS DP) is
provided, or this can be downloaded from the Internet (
http://www.nord.com/
).
Typically, this series of devices is installed directly on a three-phase asynchronous motor. Alternatively,
there are optional accessories for mounting the devices in the vicinity of the motor, e.g. on a wall or the
frame of a machine.
In the simplest configuration, even without an EEPROM, there is the possibility of setting all important
parameters via two potentiometers and eight DIP switches. LEDs are provided for the diagnosis of the
operating status. The use of a control module is therefore not absolutely necessary.
In order to gain access to all parameters, the internal RS232 PC interface (RJ12) can be used, or an
optional SimpleBox or ParameterBox may be used. In this case, the parameter settings which have been
changed by the operator are stored in the plug-in EEPROM. The EEPROM must then always remain
plugged in during operation.
ATTENTION
For changes to the frequency inverter software V 1.2 R0, the structure of individual
parameters has been changed for technical reasons.
(E.g.: up to version V 1.1 R2, (P417) was a simple parameter. As of version V 1.2. R0 this has been
divided into two arrays ((P417) [-01] and [-02]))
When plugging an EEPROM from a frequency inverter with an earlier software version into
a frequency inverter with a software version higher than V 1.2, the stored data is
automatically adapted to the new format. the new parameters are saved in the default
settings. Correct functioning is therefore ensured.
However, it is not permissible to plug an EEPROM with a software version higher
than V 1.2 into a frequency inverter with a lower software version, as this may lead to
a complete loss of data.
Summary of Contents for SK 200E Series
Page 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Page 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Page 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Page 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Page 263: ...10 Keyword index BU 0200 GB 263...
Page 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Page 265: ...The Nordac SK 200E is available to order from www inverterdrive com...