NORDAC SK 200E Manual
62
Subject to technical alterations BU
0200
GB
3.2.2
Installation of external technology units SK TU4-…
WARNING
Installations should only be made by qualified personnel, in strict compliance with the
warning and safety information.
Modules must not be inserted or removed unless the device is free of voltage. The slots
can only be used for the intended modules.
Installation
of the technology unit at a location
away from
the frequency inverter
is possible
with an additional wall-mounting kit
SK TIE4-WMK-TU.
Together with a connection unit SK
TI4-TU-BUS(-C) or SK
TI4-TU-NET(-C) the technology units
SK TU4-…(-C) form a discrete functional unit. This can be screwed to the SK 200E frequency inverter or
can be installed independently by means of an optional wall-mounting kit SK TIE4-WMK-TU. In order to
ensure reliable operation, the length of the cable between the module and the frequency inverter should not
exceed 30m.
3.2.2.1 Dimensions
As a functional unit in combination with an SK TI4-TU-… connection unit, the SK TU4-… has the following
dimensions.
3.2.2.2
Adapter unit SK TI4-TU-BUS(-C) and SK TI4-TU-NET(-C)
Various cable glands, protected with blank plugs are fitted to the sides of
the housing of the BUS or mains adapter unit.
The following holes are available for the cable glands:
•
2 x 1
M20 x 1.5 (at side)
•
4
M16 x 1.5 (underside)
•
2
M25 x 15 (at rear, without blank plugs)
The transparent screw connection at the top right (M20 x 1.5) (only SK TI4-TU-BUS(-C)) is used for access
to the diagnostic interface (RJ12 socket, interface RS232/RS485). The top left screw connector is not used.
136
91*
95
136
58
Fig.: SK
TIE4-WMK-TU
wall-mounting kit
Fig.:
Functional unit SK TU4-… and SK TI4-TU-… with
wall-mounting kit SK TIE4-WMK-TU
* For SK TU4-…-M12 modules:
99 mm
(without cover cap for M12 plug)
108 mm
(with cover cap for M12 plug)
155
Thickness of material: approx. 3.5 mm
Example:
external BUS adapter unit SK TI4-TU-BUS
Summary of Contents for SK 200E Series
Page 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Page 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Page 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Page 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Page 263: ...10 Keyword index BU 0200 GB 263...
Page 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Page 265: ...The Nordac SK 200E is available to order from www inverterdrive com...