NORDAC SK 200E Manual
172
Subject to technical alterations BU
0200
GB
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
19 =
... 29 reserved
For Posicon functions see BU 0210
30 = Status Dig
ital
-In 1
*
High
31 = Status Dig
ital
-In 2
*
High
32 = Status Dig
ital
-In 3
*
High
33 = Status Dig
ital
-In 4
*
High
39 = STO inactive
*
High
Details for the
use of the bus
systems can be
found in the
relevant
supplementary
bus manual.
*) (P546[-01]…[-03]) = 20
P435
[-01]
[-02]
Dig. out. scaling
(Standardisation of digital output)
[-01] =
Digital output 1,
Digital output of the frequency inverter
[-02] =
reserved
-400 ... 400 %
{ 100 }
Adjustment of the limit values of the output function. For a negative value, the output function
will be output negative.
Reference to the following values:
Current limit (3) = x [%]
⋅
P203 >Rated motor current<
Torque current limit (4) = x [%]
⋅
P203
⋅
P206 (calculated rated motor torque)
Frequency limit (5) = x [%]
⋅
P201 >Rated motor frequency<
P436
[-01]
[-02]
Dig
ital
out
put
hyst
eresis
S
[-01] =
Digital output 1,
Digital output of the frequency inverter
[-02] =
reserved
0 ... 100 %
{ 10 }
Difference between switch-on and switch-off point to prevent oscillation of the output signal.
P460 Time
watchdog
S
0.0 / 0.1 ... 250.0 s
{ 10.0 }
0.1 ... 250.0
=
The time interval
between the expected watchdog signals (programmable
function of digital inputs P420 – P425). If this time interval elapses without an
impulse being registered, a switch-off and error message E012 are actuated.
0.0 =
Customer error:
As soon as a high-low flank or a low signal is detected at a digital
input (function 18) the FI switches off with error message E012.
Summary of Contents for SK 200E Series
Page 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Page 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Page 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Page 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Page 263: ...10 Keyword index BU 0200 GB 263...
Page 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Page 265: ...The Nordac SK 200E is available to order from www inverterdrive com...