3 Options
BU 0200 GB
Subject to technical alterations
75
3.4.3.6 Assignment
of
functions
The assignment of functions for the digital and analog inputs and outputs is made in the following
parameters of the frequency inverter.
Parameter
Function designation
P400
Setpoint input function
P401
External analog input mode
P402
External analog input matching 0%
P403
External analog input matching 100%
P417
Offset analog output
P418
Function analog output
P419
Standardisation, analog output
P480
Function of BUS IO In bits
P481
Function of BUS IO Out bits
P482
Standardisation of BUS IO Out bits
P483
Hysteresis of BUS IO Out bits
The parameters of the IO module are used exclusively for information and testing purposes. Exception:
•
(P161)
(
→
Matching of the filter settings for the IO signals),
•
(P162)
(
→
Toggling between normal and broadcast operation) and
•
(P163)
(
→
Inversion of the analog output signal)
3.4.3.7 Broadcast
operation
In "broadcast mode" (parameter (P162)) it is possible to make up to two I/O - modules available in parallel
for a maximum of four frequency inverters. The prerequisite for this is that the FIs are on a common system
bus and no frequency inverter address has been assigned more than once (see Section 5.1.1).
The frequency inverters therefore have common access to the I/Os and evaluate the input signals according
to their own FI parameterisation. Output signals from these frequency inverters, which are sent to the
common I/O module are subjected to an "OR" logic internally by the module. I.e. a digital output
(SK TU4-IOE-…) is set as soon as one of the four frequency inverters accesses it. In addition, the highest
analog value is available via the analog output of the I/O extension module.
Summary of Contents for SK 200E Series
Page 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Page 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Page 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Page 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Page 263: ...10 Keyword index BU 0200 GB 263...
Page 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...