NORDAC SK 200E Manual
144
Subject to technical alterations BU
0200
GB
6.1.2
Basic parameters
(Frequency inverter)
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
P100 Parameter
set
S
Selection of the parameters sets to be parameterised. 4 parameter sets are available. All
parameter set-dependent parameters are identified by
P
.
The selection of the operating parameter set is performed via a digital input or the Bus control.
Switching can take place during operation (online).
Setting
Digital input
function [8]
Digital input
function [17]
LEDs
SimpleBox
0 =
Parameter set 1
Low
Low
1
2
1 =
Parameter set 2
High
Low
2
1
2 =
Parameter set 3
Low
High
1
2
3 =
Parameter set 4
High
High
2
1
0 ... 3
{ 0 }
If enabled via the keyboard (SimpleBox, PotentiometerBox or ParameterBox), the operating
parameter set will match the settings in P100.
P101
Copy parameter set
S
0 ... 4
{ 0 }
After confirmation with the OK key, a copy of the parameter set selected in P100 >Parameter
set< is written to the parameter set dependent on the value selected here.
0 = Do not copy
1 = Copy actual to P1
: copies the active parameter set to parameter set 1
2 = Copy actual to P2
: copies the active parameter set to parameter set 2
3 = Copy actual to P3
: copies the active parameter set to parameter set 3
4 = Copy actual to P4
: copies the active parameter set to parameter set 4
P102 Acceleration
time
P
0 ... 320.00 s
{ 2.00 }
Acceleration time (acceleration ramp) is the time corresponding to the linear frequency rise from
0Hz to the set maximum frequency (P105). If an actual setpoint of <100% is being used, the
acceleration time is reduced linearly according to the setpoint set.
The acceleration time can be extended by certain circumstances, e.g. FI overload, setpoint lag,
smoothing, or if the current limit is reached.
Notes on ramp gradient:
Amongst other things, the ramp gradient is governed by the inertia of the rotor.
A ramp with a gradient which is too steep may result in the "inversion" of the motor.
In general, extremely steep ramps (e.g.: 0 - 50Hz in < 0.1 s) should be avoided, as may cause
damage to the frequency inverter.
P103 Deceleration
time
P
0 ... 320.00 s
{ 2.00 }
Deceleration time (braking ramp) is the time corresponding to the linear frequency reduction from
the set maximum frequency (P105) to 0Hz. If an actual setpoint <100% is used, the deceleration
time reduces accordingly.
The deceleration time can be extended by certain circumstances, e.g. by the selected >Switch-off
mode< (P108) or >Ramp smoothing< (P106).
Notes on ramp gradient:
See parameter (P102)
Summary of Contents for SK 200E Series
Page 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Page 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Page 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Page 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Page 263: ...10 Keyword index BU 0200 GB 263...
Page 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Page 265: ...The Nordac SK 200E is available to order from www inverterdrive com...