NORDAC SK 200E Manual
178
Subject to technical alterations BU
0200
GB
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
P509
Source control word
S
0 ... 4
{ 0 }
Selection of the interface via which the FI is controlled.
0 = Contr
ol
term
inals
or keyb
oard
control
**
with the SimpleBox (if P510=0), the
ParameterBox or via BUS I/O Bits.
1 = Contr
ol
terminal
s
only *
, the FI can only be controlled via the digital and analog input
signals or via the Bus I/O Bits.
2 = USS*
, the control signals (enable, rotation direction, etc.) are transferred via the RS485
interface, the setpoint via the analog input or the fixed frequencies.
3 = System bus*
4 = System bus broadcast *
*) Keyboard control (SimpleBox, ParameterBox, PotentiometerBox) is blocked,
parameterisation is still possible.
**) If the communication during keyboard control is interrupted (time out 0.5 sec), the
FI will block without an error message.
NOTE:
For details of the optional bus systems, please refer to the relevant supplementary bus manuals
(BU02x0).
-
www.nord.com
–
As an alternative to parameterisation, switchover to
system bus broadcast
can also be made
via DIP switch 3.
P510
[-01]
[-02]
Source setpoint
S
Selection of the setpoint source to be parameterised.
[-01] = Source, main set
point
value
[-02] =
Source, 2
nd
(auxiliary)
setpoint
value
Selection of the interface via which the FI receives the setpoint.
0 ... 4
{ [-01] = 0 }
{ [-02] = 0 }
0 = Auto:
The source of the auxiliary setpoint is
automatically derived from the setting in the
parameter P509 >Interface<
1 = Contr
ol
terminal
s
only
, digital and analog inputs
control the frequency, including fixed frequencies
2 = USS
3 = System bus
4 = System bus broadcast
P511
USS Baud rate
S
Setting of the transfer rate (transfer speed) via the RS485 interface. All bus participants must
have the same baud rate setting.
0 ... 3
{ 3 }
0 = 4800 baud
1 = 9600 baud
2 = 19200 baud
3 = 38400 baud
P512 USS
address
0 ... 30
{ 0 }
Setting the FI Bus address.
Summary of Contents for SK 200E Series
Page 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Page 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Page 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Page 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Page 263: ...10 Keyword index BU 0200 GB 263...
Page 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Page 265: ...The Nordac SK 200E is available to order from www inverterdrive com...