NORDAC SK 200E Manual
190
Subject to technical alterations BU
0200
GB
Parameter
Setting value / Description / Note
Device
Supervisor
Parameter
set
P705
[-01]
...
[-05]
DC l
i
nk volt
age
last er
ror
1...5
S
0 ... 1000 V DC
This parameter stores the link voltage that was being delivered at the time the error occurred.
The values of the last 5 errors are stored.
With the SimpleBox, the corresponding memory location 1...5- (Array parameter) must be
selected and confirmed using the OK key to read the stored error code.
P706
[-01]
...
[-05]
P
arameter
set, last
error 1...5
S
0 ... 3
This parameter stores the parameter set code that was active when the error occurred. Data for
the previous 5 faults are stored.
With the SimpleBox, the corresponding memory location 1...5- (Array parameter) must be
selected and confirmed using the OK key to read the stored error code.
P707
[-01]
...
[-03]
Software version
/ revision
0.0 ... 9999.9
This parameter shows the software and
revision numbers in the FI. This can be
significant when different FIs are assigned
the same settings.
Array [-03] provides information about any
special versions of the hardware or
software A zero stands for the standard
version.
[-01] =
Software version,
version number (V1.0)
[-02] = Software revision,
revision number (R1)
[-03] = Special version
, of the
hardware/software (0.0)
P708
State of digital in
puts
Displays the status of the digital inputs in binary/hexadecimal code. This display can be used to
check the input signals.
Bit 0 =
Digital input 1
Bit 1 =
Digital input 2
Bit 2 =
Digital input 3
Bit 3 =
Digital input 4
Bit 4 =
PTC resistor input
Bit 4
Bits 3 -0
Minimum value
0
0
0000
0
Binary
hex
Maximum value
1
1
1111
F
Binary
hex
00000 ... 11111
(bin)
or
00 ... 1F
(hex)
SimpleBox:
The binary Bits are converted into a hexadecimal value and displayed.
ParameterBox:
The Bits are displayed with increasing values from right to left (binary).
Summary of Contents for SK 200E Series
Page 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Page 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Page 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Page 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Page 263: ...10 Keyword index BU 0200 GB 263...
Page 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Page 265: ...The Nordac SK 200E is available to order from www inverterdrive com...